Lighted Suction Handles for Cerumen Removal (1 Light Source, 1 Magnification Lens, 25 Lighted Suction Handles)
Bionix has combined the innovation of the Lighted Ear Curette with the efficiency of a suction device. The combination provides the ability to quickly remove cerumen or foreign bodies with the utmost ease and safety.
Features & Benefits
VersatilityRemoval of soft, viscous cerumen or large plugs. Also effective for foreign bodies.
Light and MagnificationLight projected to the tip of the suction handle, enhanced by magnification, provides the most important aspect of any procedure, complete visualization.
Suction
Suction as a tool eliminates the top down sweeping motion of a curettage procedure reducing the risk of trauma to the ear canal.
Safety
Thumb controlled suction release on the handle provides procedural safety.
Assembly/Disassembly:
- To assemble the Lighted Suction Handle, insert the blunt end of the tip
into the light source by aligning the pegs with the grooves inside the light
source. Push down and twist FIRMLY clockwise until rotation stops.
This will lock the handle into place and activate the light.
NOTE: This product is a spring-loaded device; improper assembly
may cause ejection of the tip.
- Attach the suction hose (extending from pump) to the barbed hose
adapter of the handle by pushing firmly.
- To attach the magnification lens, snap the lens onto the neck of the
blue light source so that the top of the lens angles toward the lighted tip.
- To disassemble, push the Lighted Suction Handle into the light source
and rotate counter clockwise to remove. The light will go off when the
tip is removed.
Instructions for Use:
- Examine the ear using an Otoscope noting the location and depth of cerumen or foreign body.
- Under the direct visualization of the ear canal (using the Lighted Suction Handle with or without magnification) carefully approach the cerumen
with your thumb removed from the fine tuning suction port on the handle.
- Once in contact with the cerumen, adjust handle pressure by gradually covering the opening until cerumen is removed or grasped against the suction tip. NOTE: Keep a cup of hot water nearby incase the cerumen suction handle becomes clogged. Drawing hot water into the Lighted Suction Handle may help clear the clog.
- Once the procedure is complete, remove the Lighted Suction Handle
from the light source and tubing then dispose of handle. Save the
magnification lens and light source for your next procedure.
The Lighted Suction Handle is intended for single-patient use. The light source and magnification lens are designed for multi-procedure use. A light source and lens are provided in each box of product.
Frequently Asked Questions
- How do they come packaged?
25 Lighted Suction Handles, 1 Light Source and 1 Magnification Lens per box.
- Are The Lighted Suction Handles individually wrapped?
Yes, the Lighted Suction Handles come individually wrapped..
- How long will the light source last?
It is designed to provide light for 25 suction procedures.
- Are they sterile?
Not necessary, not used in a sterile environment.
Product Offering
BX2625 - Lighted Suction for Cerumen Removal (1 Light Source, 1 Magnification Lens, 25 Lighted Suction Handles)
Purchase separately:-
BX2630 - Suction Pump
BX2635 - Replacement tubing
BX2200 - Extra Light Source
BX2299 - Light Source Lanyard
BX2265 - Pack of 5 Magnification Lenses